Low Urgency Notification Types
Low urgency notification types for G6.
Low urgency notifications are:
-
Device error
-
Low gas
-
Sensor under limit (UL)
Device error The device error notification is activated when G6 detects a component (sensor, hardware, firmware, communication, UI) that is not operating correctly. When you acknowledge the notification, G6's Home screen and banner reflect the error status. Important: If G6 has a device error that directly affects its ability to display data, the screen impacted turns orange and displays three dashes (---) as the reading. In the example shown on the right, the device is displaying a sensor reading failure where there is no historical/logged peak value, future values cannot be logged, and STEL cannot be calculated. For assistance troubleshooting device errors, contact your distributor or Blackline Safety Technical Support. | |
Low gas The low gas notification is activated when G6 detects a low gas event. If Live gas display is enabled, the live gas value is also displayed. When the notification is activated, G6 immediately connects to Blackline Live and if configured, sends an email or SMS message to the notification profile identified contacts in Blackline Live. When you acknowledge the notification, G6's Home screen and banner reflect the low gas status until the low gas event is resolved. Note:
The device's yellow light pattern persists after you acknowledge/mute the low gas notification. If the muted low gas event conditions persist past 120 seconds, the low gas notification is reactivated with lights, sounds, and vibration. Following the low gas notification, the logged peak gas value of the low gas event displays on the Gas options screen. The screen shows the peak value recorded and the time it occurred until a new peak is reached, the peak value is manually reset, or the peak value automatically resets. For more information on viewing and resetting gas readings, see Viewing and Resetting Gas Readings. | |
|
Sensor under limit (UL) The sensor under limit (UL) notification is activated when G6 detects a UL gas event. When you acknowledge the notification, G6's Home screen, banner, and yellow light pattern reflect the UL status. If the muted UL event conditions persist past 120 seconds, the low gas notification reactivates. Important:
Following a UL notification, no peak is logged as the UL event type is closely related to a device or sensor error. To resolve the UL event, Blackline Safety recommends that you calibrate G6. For more information, see Manually Calibrating G6 Using a Calibration Cap and Tube. | |