Viewing and Resetting Gas Readings

How to view and reset peak gas readings for G6.

Use the Gas options feature to view and reset the following gas readings for your device:

  • Peak gas reading
    Note:

    If unchanged for 24 hours, G6’s peak gas readings automatically reset.

  • Short term exposure limit (STEL) reading
    Note:

    STEL is applicable to H2S, CO, or SO2 devices only. STEL is not applicable to O2 devices.

  • Time weighted average (TWA) reading
    Note:

    TWA is applicable to H2S, CO, or SO2 devices only. TWA is not applicable to O2 devices. If the TWA is unchanged for configured time interval (default: 8 hours), G6’s TWA reading automatically resets.

  1. From the Home screen, select by pressing the center button.
  2. Using the navigation buttons, scroll through the Global Navigation menu, then select Gas options by pressing the center button ().

    The Gas options screen opens, displaying the most recent peak reading, TWA reading, and STEL reading recorded by G6.

    Note:

    For O2 devices, the peak enrichment and peak depletion gas readings display.

    Note:

    Gas readings above the sensor maximum result in an over limit (OL) reading.

  3. To reset the peak reading, select by pressing the right button.
  4. Using the navigation buttons, scroll through the menu, then select Reset peak by pressing the center button ().

    The Reset peak screen opens, displaying:

    • Most recently logged peak reading

    • Low/high urgency gas setpoints

  5. For H2S, CO, or SO2 devices: To reset the peak gas value to zero, select by pressing the right button.
    Note:

    To cancel the procedure and exit at any time, select by pressing the left button.

    G6 resets the peak gas value.

  6. For O2 devices: To reset the peak enrichment and depletion values to zero, select by pressing the right button.
    Note: Scroll between the peak enrichment and depletion readings by pressing the center button ( ).

    G6 resets the peak enrichment and depletion values to zero.

  7. Once the value is successfully reset, select by pressing the right button to return to the Gas options screen.