Help Center

Search the Help Center

Pump Run

Used when continuous sampling is needed:
  • Pump runs continuously without any timeout.

  • No timeout: user must manually exit this mode.

  • Yellow LED flashes every 30 seconds while the pump is active.

  • Pump cartridge required.

Blackline Live administrators may configure supported cartridges with either of the following settings:
  • Pump-run on Startup: When enabled, the device automatically goes into pump mode by default.

  • Manual Pump-run: When the Pump-run on Startup setting is disabled, users must manually select the pump-run setting on the device.