Help Center

Search the Help Center

Turning On Pump Run Mode

The procedure to turn on Pump Run Mode on the G8 device.

To perform the following steps, your G8 must be equipped with a multi-gas pump cartridge and pumped modes. Pumped modes can be configured in Blackline Live. For more details, see LEL Functional Safety.

  1. Select the target pumped mode from the Modes menu or Modes screen.
    G8 tests the pump flow before entering the mode.
  2. Follow the steps on G8's screen to complete the pump block test, blocking, and unblocking the gas flow when prompted.
  3. Press the center button to stop the test at any time and return G8 to Normal mode. If the pump block test fails, check G8's tubing and try to activate the mode again.
When the test completed, the Status screen's color scheme inverts and the banner indicates you are in the mode selected. If your cartridge includes an LEL sensor, the yellow LED light illuminates to visually notify you that the pump is running.Status screen banner: Pump run mode