Help Center

Search the Help Center

G7 Cartridge Comparison

G7 is compatible with Cartridge F1 and Cartridge F2. Cartridge F1 is the previous generation of Blackline Safety's device cartridge. Cartridge F2 is the current generation of device cartridge that was released on May 1, 2025.

Cartridge F1 and Cartridge F2 are both available in four cartridge types: standard (lone worker), single-gas, multi-gas diffusion, and multi-gas pump cartridges. A-CART is a version of the Pump Cartridge F2 and only operates in pump mode, regardless of configuration.

Note:

G7 firmware version 3.505 must be installed on your device to use the Pump Cartridge F2 and the A-CART. The A-CART must be used for pumped sensor configurations that include an LEL-IR sensor.

G7 can be configured with a Standard Cartridge, also known as a Lone Worker cartridge, without gas-detection capabilities. This cartridge does not support gas detection, calibration, or bump testing. It is used for personal safety monitoring features like SOS alerts and check-ins.

The following comparison chart summarizes the features of each cartridge:

StandardSingleMulti (diffusion)Multi (pump)
Text messaging
Fall detection
No-motion detection
SOS alert
Check-in timer
Configuration modes
Receive voice calls
Push-to-talk (PTT)
Single gas detection
Multi-gas detection
Pump enabledOptional
Low-gas notification
Under-limit notification
High-gas notification
STEL notification
TWA notification
Over-limit (OL) notification