Installing EXO Diffusion Components
To upgrade EXO Diffusion, or to convert from EXO Pump to EXO Diffusion, you will install the diffusion components.
You will need:
-
EXO with the previous components removed
-
EXO Diffusion components or EXO Diffusion Upgrade kit (ACC‑G7EXO‑DIFFUSION-MOD-KIT)
-
Screwdriver (#2 Phillips)
The previous EXO Diffusion or EXO Pump components must be completely uninstalled before proceeding.
- Install the diffusion chamber:
- Using your fingers, attach the diffusion chamber coupling to EXO’s inlet tubing.
- Carefully push the tubing into EXO’s front enclosure.
- Slide the diffusion chamber into its slot and secure the chamber using two screws and washers, ensuring they are snug but not over-tight.
- Install the diffusion module:
- Insert the device’s gas sensor cartridge by sliding it into it’s slot in the diffusion chamber.
- Place the diffusion cartridge cover on EXO, ensuring that you properly orient the cartridge cover over top of the device’s front enclosure. Tighten the cartridge’s screws, ensuring they are snug but not over-tight.
EXO Diffusion is ready for use.
Note:
When bump testing or calibrating EXO Diffusion in windy conditions, the wind guard is required to help regulate the flow and concentration of gas delivered to the sensors. Warning:
Always remove the wind guard as soon as EXO has been successfully bump tested and calibrated. Failure to do so will slow down EXO’s response to hazardous gases. For detailed instructions on installing and using the wind guard, refer to the EXO Technical User Manual. | |