Gas Inlets and Sampling (EXO Only)
Unlike G7 and G8, EXO uses an internal pump configuration with multiple gas inlets for remote sampling. EXO’s pump and inlet system is internal to the pump configuration and not housed inside a swappable cartridge.
The EXO Pump configuration includes four dedicated gas sampling inlets and a separate manual calibration inlet. These features allow EXO to sample gases remotely from confined spaces or remote locations using attached tubing.
This section explains how to use the manual calibration inlet, assign pump inlets, configure sampling cycles, adjust sample timing, and test for pump blockages.
This section applies only to EXO’s 4-inlet pump module, not the gas expansion module.