High Urgency Notification Types
High urgency notifications are:
-
High gas
-
Overlimit (OL)
-
SOS alert
High gas The high gas notification is activated when EXO detects gas levels above the high gas concentration threshold configured by your Blackline Live administrator. Note:
A device equipped with an O2 sensor will activate high gas notifications in both oxygen-deficient and oxygen‑enriched environments. When you acknowledge the high gas notification, your device's banner and lights will reflect the high gas status until the gas conditions dissipate and the high gas event is resolved. If gas levels remain above the high threshold for more than 60 seconds, the high gas notification will retrigger with lights and sound until the high gas event is resolved. EXO is equipped with a high gas countdown timer that is configurable (enabled/disabled) by your Blackline Live administrator. Enabling the countdown timer can help reduce the frequency of false high gas event notifications. If enabled, the countdown timer will delay connecting to Blackline Live for 30 seconds. If AlertLink is enabled, G7c and EXO devices within the configured proximity radius of your device at the time of the triggering event will receive a low urgency notification and a message with the alert details. Note:
You can exclude EXO from receiving AlertLink messages. Following the high gas notification, the logged peak value of the high gas event is displayed on the Gas options screen. The device will show the peak value recorded until a new peak is reached, or the peak value is reset during a power cycle of the device. |
Over limit (OL) The sensor over limit (OL) notification is activated when EXO detects that the gas reading has exceeded the range of its sensor. When you acknowledge the OL notification, EXO's banner and lights will reflect the high gas status until the gas conditions dissipate and the OL event is resolved. If AlertLink is enabled, G7c and EXO devices within the configured proximity radius of your device at the time of the triggering event will receive a low urgency notification and a message with the alert details. Note:
EXO may be excluded from receiving AlertLink messages. Following the OL notification, the OL event is displayed on the Gas options screen. The device will show the peak value recorded until a new peak is reached, or the peak value is reset during a power cycle of the device. |
SOS alert If you require assistance, you can manually send an SOS to monitoring personnel and request immediate help to your location by pulling the SOS latch. When you acknowledge the notification, your device's banner and lights will reflect the SOS status until the SOS event is resolved. Note:
The SOS alert notification is configurable by your Blackline Live administrator. If AlertLink is enabled, G7c and EXO devices within the configured proximity radius of your device at the time of the triggering event will receive a low urgency notification and a message with the alert details. Note:
EXO may be excluded from receiving AlertLink messages. |