Install EXO interface port accessories as shown in the following electrical diagrams to ensure intrinsic safety.

Table 1. Interface port parameters – Low-side switch
Table 2. Input entity parameters (low-side switch)
Terminal Ui Ii Pi Ci Li
Pin 1 to pin 2 (GND)24Vdc3.33A1.25W0F0H
Table 3. Interface port parameters – pins 3 & 4
Table 4. Output entity parameters
Terminal Uo Io Po Co Lo Lo/Ro*
Pin 3 to pin 2 (GND)20.76Vdc93mA0.479W0.194uF4.1mH18.2uH/Ω
Pin 4 to pin 2 (GND)3.6Vdc1.21A3W1000uF24.3uH21.9uH/Ω

* Li may be greater than Lo and the cable length restrictions due to cable inductance (Lcable),

and can be ignored if both of the following conditions are met:

Lo/Ro ≥ Li/Ri

Lo/Ro ≥ Lcable/Rcable

Table 5. Interface port functional parameters

Table 6. Functional output parameters for interface ports A and B
Terminal Uo Io Po Co Lo
Pin 3 to pin 2 (GND)18Vdc48mA479mW0.194uF4.1mH
Pin 4 to pin 2 (GND)3.2Vdc1000mA3.0W1000uF24.2uH

Io and Po is reduced if both pin 3 and pin 4 are used simultaneously.

Table 7. Functional input parameters (low-side switch) for interface ports A and B
Terminal Ui Ii Pi Ci Li
Pin 1 to pin 2 (GND)24Vdc3.33A1.25W0F0H
Table 8. Interface port functional parameters with barriers

Note:

A barrier is required for each interface port. The diode barrier and dual barrier can be individual units or a joint unit.

Table 9. Functional output parameters for interface ports A and B
Terminal Uo Io Po Co Lo
Pin 3 to pin 2 (GND)18Vdc48mA479mW0.194uF4.1mH
Pin 4 to pin 2 (GND)3.2Vdc1000mA3.0W1000uF24.2uH

Io and Po is reduced if both pin 3 and pin 4 are used simultaneously.

Table 10. Functional input parameters (low side switch) for interface ports A and B
Terminal Ui Ii Pi Ci Li
Pin 1 to pin 2 (GND)24Vdc3.33A1.25W0F0H