A listing of the operational notifications available on G8.

Operational notifications include:

  • Low battery
  • Lost connection
  • Bump test due (optional)
  • Bump test reminder (optional)

  • Calibration due (optional)
  • Calibration reminder (optional)
  • Timer done
Low Battery

The low-battery notification interval is configurable between 0%-70% by your Blackline Live administrator

The low-battery notification is activated when G8 detects that it is operating below the configured low battery threshold. G8 remains in low-battery status until it is charged above the configured threshold.
Low Battery notification example

Low Battery banner message on Status screen

Lost Connection

The lost connection interval (in minutes) is configurable by your Blackline Live administrator.

The lost connection notification is activated when G8 fails to connect with Blackline Live for the configured time interval (e.g., five minutes).
Network Lost notification exampleNetwork Lost banner message on Status screen
Bump Test Due

The bump test due notification is activated when:

  • G8 is overdue for a bump test, based on your organization's configured bump test interval.
  • A bump test is attempted but fails.
Following the bump test due notification, a message displays in the banner until the device is successfully bump tested. The device remains fully functional.
Bump Test Due notification exampleBump test due banner message on Status screen
Bump Test Reminder

The bump test reminder notification interval is configurable by your Blackline Live administrator. Your Blackline Live administrator can also mute the bump test reminder notification light, sound, and vibration patterns.

The bump test reminder notification is activated when G8 is due for a bump test within the interval (hours or days) as configured in Blackline Live.

Calibration Due

The calibration due notification is activated when:

  • G8 is overdue for calibration based on your organization's configured interval.
  • Calibration is attempted but fails.
Following the calibration due notification, a message displays in the banner until the device is successfully calibrated. The device remains fully functional.
Calibration notification exampleCalibration due banner on Status screen

Calibration Reminder

The calibration reminder notification interval is configurable by your Blackline Live administrator. Your Blackline Live administrator can also mute the calibration due notification light, sound, and vibration patterns.

The calibration reminder notification is activated when G8 is due for calibration within the interval (hours or days) as configured in Blackline Live.