Help Center

Search the Help Center

Gas Sensor Specifications

Gas Sensor Type Range Resolution
Ammonia (NH3)Electrochemical0–100 ppm0.1 ppm
High-range ammonia (NH3)Electrochemical0–500 ppm1 ppm
Carbon monoxide (CO)Electrochemical0–500 ppm1 ppm
High-range carbon monoxide (CO)Electrochemical0–2000 ppm5 ppm
Hydrogen resistant carbon monoxide (CO-H)Electrochemical0–500 ppm1 ppm
Carbon dioxide (CO2)NDIR0–50,000 ppm50 ppm
Chlorine (Cl2)*Electrochemical0–20 ppm0.1 ppm
Chlorine dioxide (ClO2)*Electrochemical0–2 ppm0.01 ppm
COSH (CO & H2S)Electrochemical0–500 ppm CO, 0–100 ppm H2S1 ppm CO, 0.1 ppm H2S
Hydrogen (H2) (UK/EU only)Electrochemical0–40,000 ppm

1% LEL

(400 ppm H2)

Hydrogen cyanide (HCN)Electrochemical0–30 ppm0.1 ppm
Hydrogen sulphide (H2S)Electrochemical0–100 ppm0.1 ppm
High-range hydrogen sulphide (H2S)Electrochemical0–500 ppm0.5 ppm
LEL-infrared (LEL-IR)NDIR0–100% LEL1% LEL

LEL-molecular property spectrometer

(LEL-MPS)

MPS0–100% LEL0.1% LEL
LEL-pellistor (LEL-P) (UK/EU Only)Catalytic bead0–100% LEL1% LEL
Nitrogen dioxide (NO2)Electrochemical0–50 ppm0.1 ppm
Oxygen (O2)Pumped electrochemical0–25% vol0.1% vol
Photoionization (PID)PID0–4,000 ppmDynamic resolution**, 0.1 ppm
Sulfur dioxide (SO2)Electrochemical0–100 ppm0.1 ppm
Note:

Check with Blackline for approval status. All specifications subject to change.

*Sensor does not work with EXO Pump

**Dependent on correction factor

***Operating pressure: 80 to 120 kPa (11.6 psi to 17.4 psi)