A/B Interface Ports
When events are triggered on EXO, A/B interface ports act as switches by sending ON or OFF signals to connected accessories. Ask your Blackline Safety distributor or sales representative for a list of EXO accessories that attach to the A/B interface ports.
Interface ports can be configured to activate when a high gas notification, low gas notification, text message, or AlertLink message event is triggered on the device.
Interface ports can also be configured to apply or remove power from connected accessories when an event occurs. For more information on configuring interface ports, refer to the Blackline Live Technical User Manual.
Cable requirements
Both of EXO's A/B interface ports are fitted with a female M12 4 pin receptacle. Electrical cables with a male M12 4 pin plug are required to connect to these ports.
EXO versions and serial numbers
Two versions of the EXO have different output port parameters. High output EXOs have serial numbers 35880xxxxx, 35882xxxxx, or 35884xxxxx. All other serial numbers are low output EXOs.
| |
Female receptacle Pin assignment M12 socket, 4-pos., A-coded, view receptacle side |
| |
Contact assignment of the M12 plug and M12 receptacles |