High-urgency Notification Types
| Notification | Description |
|---|---|
| Over Limit (OL) | Triggered when gas levels exceed the sensor’s measurable range, indicating dangerously high concentrations. |
| High Gas | Activated when a specific gas exceeds a configured high threshold, signaling a potential safety risk. |
| Short-Term Exposure Limit (STEL) | Triggered when gas levels exceed the configured short-term exposure limit. |
| Time-Weighted Average (TWA) | Triggered when long-term exposure exceeds the configured time-weighted average. |
| LEL > 60% | Triggered when the lower explosive limit reaches 60%, indicating a potentially explosive atmosphere. |
| LEL Over Limit | Triggered when LEL levels exceed the measurable range of the sensor. |
| Gas Notification Muted | Notification remains active after being muted. Lights stay red, and the audible tone alternates on/off in a repeating pattern. |