NotificationDescription
Over Limit (OL)Triggered when gas levels exceed the sensor’s measurable range, indicating dangerously high concentrations.
High GasActivated when a specific gas exceeds a configured high threshold, signaling a potential safety risk.
Short-Term Exposure Limit (STEL)Triggered when gas levels exceed the configured short-term exposure limit.
Time-Weighted Average (TWA)Triggered when long-term exposure exceeds the configured time-weighted average.
LEL > 60%Triggered when the lower explosive limit reaches 60%, indicating a potentially explosive atmosphere.
LEL Over LimitTriggered when LEL levels exceed the measurable range of the sensor.
Gas Notification MutedNotification remains active after being muted. Lights stay red, and the audible tone alternates on/off in a repeating pattern.